High quality transformer coil supplier factory: How to deal with the failure of the main transformer cooler? The failure of the main transformer cooler may cause the temperature of the main transformer to rise, thereby affecting the normal operation of the transformer. Therefore, if it is found that the main transformer cooler is faulty, it is necessary to take timely measures to deal with it. Here are some possible approaches: Replacing Faulty Cooler Parts: If some parts in your cooler are damaged or malfunctioning, consider replacing those parts to restore the cooler to working properly. The specific operation needs to be carried out according to the structure of the cooler and the cause of the failure. Clean the cooler: If the pipes or cooling fins in the cooler are clogged or dirt accumulates, it may reduce the cooling effect and affect the normal operation of the transformer. The way of cleaning can be used to remove the dirt and sundries inside the cooler to restore the normal operation of the cooler. See extra info at https://www.canwindg.com/products-20760.
What is eddy current? What are the disadvantages of eddy current generation? Eddy current refers to a kind of current generated in the conductor, which is the induced current caused by the change of the magnetic field. The eddy current forms a circular current flow path in the conductor, and this current forms a motion state similar to an eddy current inside the conductor, so it is called an eddy current. The generation of eddy currents has the following disadvantages: Energy loss: Eddy currents create circular currents in conductors, which generate heat as they flow continuously in conductors. Since the generation of eddy currents is caused by changes in the magnetic field, in equipment such as transformers and motors.
As a professional laser machine manufacturer & supplier, Canwin specialized in laser machine manufacturing, including laser welding machines and laser cutting machines.Continuous fiber laser hand-held welding equipment is a special equipment for metal processing such as hardware, building materials and handicrafts launched by CANWIN. Small equipment, easy to move and handling, flexible and convenient operation, can realize outdoor welding, suitable for all kinds of complex sheet metal hardware welding. Welding efficiency is fast.
The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
As a professional electrical equipment manufacturer in China, Canwin specialized in dry type transformers, electrical equipment for over 20 years. Canwin electrical products manufacturer adopts large-scale, intelligent electrical machinery equipment manufacturing mode, and strive to achieve high quality, high efficiency, low cost operation.Our electrical machinery products including cut to length lines, china slitting lines and foil winding machines.
Canwin, a electrical equipment manufacturer mainly produces 150 model oil-type transformer core shearing equipment below 1 600KVA, 300 model dry type transformer core shearing equipment below 6300KVA, 400 model special transformer core shearing equipment below 12500KVA and 600 model special transformer core shearing equipment below 63000KVA. 800 model extra transformer core shearing equipment, 1000 model extra transformer core shearing equipment, the type 1250 model CRGsilicon steel CNC slitting machine, and the dry type transformer core under 110KV automatic cutting and laminated processing center, oil transformer core automatic cutting robot automatic lamination processing center, reactor cutting center below 35Kv, 220KV high voltage china transformer equipment tc. Transformer core & transformer coil manufacturing and assembly, including coil windings using copper and silver alloyed or continuously transposed copper cable.Canwin hire famous designer in Europe as our senior consultant, and germany Siemens as our strategic partner. The products have formed 5 series and more than 50 specifications.Canwin is your best choice of electrical equipment suppliers.
As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Read additional details at https://www.canwindg.com/
The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.
Maintaining high power quality requires careful management of harmonic currents and other potential disturbances on transmission lines. This is crucial not only for the efficient performance of transformer core cutting machine but also for the overall reliability and safety of the power system. Voltage unbalance is a significant power quality issue that can severely affect the efficiency of electrical equipment. It occurs when the voltages or currents in a three-phase system are not equal in magnitude or are not separated by exactly 120 degrees. Voltage unbalance can cause several problems in electrical equipment. For instance, it can lead to a decrease in the efficiency of electric motors by causing a reduction in torque and an increase in vibration and noise. This not only affects the performance of the motor but also shortens its lifespan. Similarly, voltage unbalance can also reduce the efficiency of transformers, leading to increased losses and overheating.